Unité de Contrôle de Procédé
(Level/Flow Process Control)
38-001 |
|
| |
|
|
|
Équipement
constitué de :
-
Contains a selection
of level & flow sensors & indicators
-
Flow controlled by
linear motorised control valve
-
On/Off and
proportional control
-
P, PI and full PID
control with autotune facility
-
Couples with
Temperature Trainer for dual loop control
-
Modern push fittings
-
Water used as the
process fluid
-
Comprehensive lab
notes and Discovery software
|
 |
|
| |
|
|
|
|
|
| |
|
|
|
Industrial Process Fault Finding Trainer 34-250
Nouveau |
|
| |
|
|
|
Caractéristiques :
Self contained
processes
Wide range of easy-to-apply
faults
Mechanical,
electrical, electronic and process component faults
Teaches fault
diagnosis and fault-finding methodology
May be used as part
of an Industrial Maintenance programme
May be driven
from external PLC
or Process Controller
Compatible with the
Feedback range of Procon controllers and software
Fully protected for
safety
Curriculum Coverage :
-
Introduction to
the
system
-
Fault-finding
methodologies
-
Fault analysis flow
charts
-
Fault-finding from
circuit diagrams
-
Fault identification
to line replaceable unit level
-
Simple electronic
fault-finding
-
Diagnostic tools
-
Maintenance
procedures
-
Process control
techniques
-
Fault-finding
processes controlled from electronic controllers
-
Interfacing to
Programmable Logic Controllers (PLCs)
- Fault-finding in PLC-based
systems
|
|
| |
|
|
|
|
|
| |
|
|
|
Pressure Process Control 38-004 |
|
| |
|
|
|
Features:
-
Safe
low pressure operation
-
Fully gauged for pressure and flow rate
-
Differential and Gauge pressure sensors
-
Current controlled (4-20mA) pneumatically operated control valve
-
Standard industrial components
-
Self-sealing outlets for manometer
-
Safety valves fitted as standard
-
Air
used as the process fluid
Curriculum Coverage:
-
Pressure safety,
familiarisation and calibration
-
I/P converter and
Pneumatic control valve
-
operation
-
Controller
familiarisation and calibration
-
Automatic control
systems
-
Serial communication
-
Pressure sensor,
transmitter and I/P converter
-
Linearity and Hysteresis
-
Pneumatic control
valve -characteristics at different pressure ranges
-
System response and
Air receiver
-
Principles of
Proportioning valve and proportional process control
|

|
|
| |
|
|
|
|
|
| |
|
|
|
Level/Flow & Temperature Process Control 38-003 |
|
| |
|
|
|
Features:
-
Contains a selection of level flow and temperature sensors and
indicators
-
Primary and secondary flow controlled by linear motorised
control valves
-
On/Off and proportional control
-
P,
PI and full PID control with autotune facility
-
Can perform dual loop cascade control
-
Modern push fittings
-
Water used as the process fluid
Comprehensive lab notes and
Discovery SoftwareThe
combined PROCON Level/Flow and Temperature Process
Control System is self-contained
and has all of the features of the individual Lev el/Flow
and Temperature systems plus Remote Set Point Control.
Remote Set-Point Control can be
affected with the PROCON Level/Flow and Temperature Process
Control System by using two Process Controllers.
The 4-20mA Analogue Remote
Set-Point input allows various forms of cascade control to be
implemented between linked or interactive control loops.
The process set-point can be
Local and Remote or Dual, selected from the front panel, or in
response to a logic input.
When Dual Set-Point is selected
the function can be ratio or bias action.
A Programmable Logic Controller
(PLC) 38-350 is also available. It can be used with the Process
Interface 38-200 to
provide an alternative control
method with on/off elements to the standard Process Controller
38-300.
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
Copyright ©, E.S.L.I 2009 |
| |
|
|
|
|
| |
|
|
|
|
|